Banner Portal
The assessment of periimplant soft tissue condition with morse taper abutment connection
PDF

Keywords

Dental implant-abutment design
Soft tissue injuries
Dental abutments
Dental implants
Gingiva
Mouth mucosa

How to Cite

1.
Lasminingrum PP, Miranda A, Carolina DN, Metta P. The assessment of periimplant soft tissue condition with morse taper abutment connection: a rapid review. Braz. J. Oral Sci. [Internet]. 2021 Aug. 23 [cited 2024 Sep. 26];21(00):e224977. Available from: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8664977

Abstract

Aim: This study aims to evaluate the clinical assessment results of periimplant soft tissue with morse taper (internal abutment connection). Methods: The study was conducted using a rapid review by searching the articles from PubMed NCBI and Cochrane by using keywords. All articles were selected by the year, duplication, title, abstract, full-text, and finally, all selected articles were processed for final review. Following clinical parameters were included; Periimplant Probing Pocket Depth (PPD), Plaque Score (PS), modified Plaque Index (mPI), Mucosal Thickness (MTh), Gingival Height (GH), periimplant mucosal zenith, Pink Esthetic Score (PES), Bleeding On Probing (BOP), Sulcus Bleeding Index (SBI), and modified Gingival Index (mGI). Results: 9 selected articles were obtained from the initial literature searching count of 70 articles. The overall samples included 326 morse taper implants. Based on the evaluation, 3 out of 4 articles reported pocket depth < 4 mm, no bleeding was reported in 2 out of 4 articles. 4 out of 4 articles reported low plaque accumulation, low soft tissue recession was reported in 3 out of 3 articles, and 4 out of 4 articles reported acceptable PES values. Conclusion: The evaluations indicate that the morse taper (internal abutment connection) has favorable assessment results based on various clinical parameters.

https://doi.org/10.20396/bjos.v21i00.8664977
PDF

References

Goiato MC, Pellizzer EP, da Silva EVF, Bonatto L da R, dos Santos DM. Is the internal connection more efficient than external connection in mechanical, biological, and esthetical point of views? a systematic review. Oral Maxillofac Surg. 2015 Sep;19(3):229-42. doi: 10.1007/s10006-015-0494-5.

Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS. Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res. 2012 Oct;23 Suppl 6:2-21. doi: 10.1111/j.1600-0501.2012.02547.x.

Ceruso FM, Barnaba P, Mazzoleni S, Ottria L, Gargari M, Zuccon A, et al. Implant-abutment connections on single crowns: a systematic review. Oral Implantol (Rome). 2017 Jan 21;10(4):349-53. doi: 10.11138/orl/2017.10.4.349.

Takei N, Carranza K. Clinical periodontology. 13th ed. Philadelphia: Elsevier; 2019. p.732-858.

Romanos GE, Delgado‐Ruiz R, Sculean A. Concepts for prevention of complications in implant therapy. Periodontol 2000. 2019 Oct;81(1):7-17. doi: 10.1111/prd.12278.

Mishra SK, Chowdhary R, Kumari S. Microleakage at the different implant abutment interface: a systematic review. J Clin Diagnostic Res. 2017 Jun;11(6):ZE10-5. doi: 10.7860/JCDR/2017/28951.10054.

Malet J, Mora F, Bouchard P. Implant dentistry at a glance. UK: Wiley-Blackwell; 2012. p.1-25.

Vetromilla BM, Brondani LP, Pereira-Cenci T, Bergoli CD. Influence of different implant-abutment connection designs on the mechanical and biological behavior of single-tooth implants in the maxillary esthetic zone: a systematic review. J Prosthet Dent. 2019 Mar;121(3):398-403.e3. doi: 10.1016/j.prosdent.2018.05.007.

Caricasulo R, Malchiodi L, Ghensi P, Fantozzi G, Cucchi A. The influence of implant-abutment connection to peri-implant bone loss: a systematic review and meta-analysis. Clin Implant Dent Relat Res. 2018 Aug;20(4):653-64. doi: 10.1111/cid.12620.

Garabetyan J, Malet J, Kerner S, Detzen L, Carra MC, Bouchard P. The relationship between dental implant papilla and dental implant mucosa around single-tooth implant in the esthetic area: a retrospective study. Clin Oral Implants Res. 2019 Dec;30(12):1229-37. doi: 10.1111/clr.13536.

Tricco AC, Langlois E V, Straus SE, editors. Rapid reviews to strenghthen health policy and systems: a practical guide. Geneva: World Health Organisation; 2017. p.1-34.

Moher D, Liberati A, Tetzlaff J, Altman DG; PRISMA Group. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. J Clin Epidemiol. 2009 Oct;62(10):1006-12. doi: 10.1016/j.jclinepi.2009.06.005.

Cooper LF, Reside G, Stanford C, Barwacz C, Feine J, Nader SA, et al. Three-Year Prospective Randomized Comparative Assessment of Anterior Maxillary Single Implants with Different Abutment Interfaces. Int J Oral Maxillofac Implants. 2019 Jan/Feb;34(1):150-8. doi: 10.11607/jomi.6810.

Heydecke G, Mirzakhanian C, Behneke A, Behneke N, Fügl A, Zechner W, et al. A prospective multicenter evaluation of immediately functionalized tapered conical connection implants for single restorations in maxillary anterior and premolar sites: 3-year results. Clin Oral Investig. 2019 Apr;23(4):1877-85. doi: 10.1007/s00784-018-2614-8.

Pessoa RS, Sousa RM, Pereira LM, Neves FD, Bezerra FJB, Jaecques SVN, et al. Bone remodeling around implants with external hexagon and morse-taper connections: a randomized, controlled, split-mouth, clinical trial. Clin Implant Dent Relat Res. 2017 Feb;19(1):97-110. doi: 10.1111/cid.12437.

Barwacz C, Stanford C, Diehl U, Cooper L, Feine J, McGuire M, et al. Pink esthetic score outcomes around three implant-abutment configurations: 3-year results. Int J Oral Maxillofac Implants. 2018;33(5):1126-35. doi: 10.11607/jomi.6659.

Kaminaka A, Nakano T, Ono S, Kato T, Yatani H. Cone-beam computed tomography evaluation of horizontal and vertical dimensional changes in buccal peri-implant alveolar bone and soft tissue: a 1-year prospective clinical study. Clin Implant Dent Relat Res. 2015 Oct;17 Suppl 2:e576-85. doi: 10.1111/cid.12286.

Cosyn J, Eghbali A, Hermans A, Vervaeke S, De Bruyn H, Cleymaet R. A 5-year prospective study on single immediate implants in the aesthetic zone. J Clin Periodontol. 2016 Aug;43(8):702-9. doi: 10.1111/jcpe.12571.

McGuire M, Scheyer E, Ho D, Stanford C, Feine J, Cooper L. Esthetic outcomes in relation to implant-abutment interface design following a standardized treatment protocol in a multicenter randomized controlled trial-a cohort of 12 cases at 1-year follow-up. Int J Periodontics Restor Dent. 2015;35(2):149-59. doi: 10.11607/prd.2341.

Pozzi A, Tallarico M, Peter K M. Three-year post-loading results of a randomised, controlled, split-mouth trial comparing implants with different prosthetic interfaces and design in partially posterior edentulous mandibles. Eur J Oral Implantol. 2014 Spring;7(1):47-61.

Gultekin BA, Gultekin P, Leblebicioglu B, Basegmez C, Yalcin S. Clinical evaluation of marginal bone loss and stability in two types of submerged dental implants. Int J Oral Maxillofac Implants. 2013 May-Jun;28(3):815-23. doi: 10.11607/jomi.3087.

Ivanovski S, Lee R. Comparison of peri-implant and periodontal marginal soft tissues in health and disease. Periodontol 2000. 2018 Feb;76(1):116-30. doi: 10.1111/prd.12150.

Hämmerle CHF, Schou S, Holmstrup P, Hjorting‐hansen E, Lang NP. Plaque‐induced marginal tissue reactions of osseointegrated oral implants: a review of the literature. 1992 Dec;3(4):149-61. doi: 10.1034/j.1600-0501.1992.030401.x.

Atassi F. Periimplant probing: positives and negatives. Implant Dent. 2002;11(4):356-62. doi: 10.1097/00008505-200211040-00015.

Prado A, Pereira J, Henriques B, Benfatti C, Magini R, López-López J, et al. Biofilm affecting the mechanical integrity of implant-abutment joints. Int J Prosthodont. 2016;29(4):381-3. doi: 10.11607/ijp.4759.

Macedo JP, Pereira J, Vahey BR, Henriques B, Benfatti CAM, Magini RS, et al. Morse taper dental implants and platform switching: the new paradigm in oral implantology. Eur J Dent. 2016;10(1):148-54. doi: 10.4103/1305-7456.175677.

Petris GP, Carli JP De, Paranhos LR, Santos PL, Benetti P, Walber M, et al. Morse taper performance: a finite element analysis study. Clinics (São Paulo). 2019 Mar 25;74:e852. doi: 10.6061/clinics/2019/e852.

Tripodi D, D’Ercole S, Iacullif F, Piattelli A, Perrotti V, Iezzi G. Degree of bacterial microleakage at the implant abutment junction in cone morse tapered implants under loaded and unloaded conditions. J Appl Biomater Funct Mater. 2015 Dec 18;13(4):e367-71. doi: 10.5301/jabfm.5000247.

Dayrell A, Noritomi P, Takahashi J, Consani R, Mesquita M, dos Santos M. Biomechanical analysis of implant-supported prostheses with different implant-abutment connections. Int J Prosthodont. 2015 Nov-Dec;28(6):621-3. doi: 10.11607/ijp.4258.

Da Silva-Neto JP, Prudente MS, Dantas TS, Senna PM, Ribeiro RF, Das Neves FD. Microleakage at different implant-abutment connections under unloaded and loaded conditions. Implant Dent. 2017 Jun;26(3):388-92. doi: 10.1097/ID.0000000000000568.

Mangano C, Mangano F, Shibli JA, Tettamanti L, Figliuzzi M, D’Avila S, et al. Prospective evaluation of 2,549 morse taper connection implants: 1- to 6-year data. J Periodontol. 2011 Jan;82(1):52-61. doi: 10.1902/jop.2010.100243.

Dani S, Prabhu A, Jain KV, Dugad S, Sindhe JR, Patil SR. Esthetic evaluation of maxillary anterior single-tooth implant by dental specialists and non-dental personnel. Int Dent Med J Adv Res. 2018;4(1):1-6. doi: 10.15713/ins.idmjar.82.

Sanz-Martín I, Sanz-Sánchez I, Noguerol F, Cok S, Ortiz-Vigón A, Sanz M. Randomized controlled clinical trial comparing two dental implants with different neck configurations. Clin Implant Dent Relat Res. 2017 Jun;19(3):512-22. doi: 10.1111/cid.12482.

Dhir S. Biofilm and dental implant: the microbial link. J Indian Soc Periodontol. 2013 Jan;17(1):5-11. doi: 10.4103/0972-124X.107466.

Pozzi A, Agliardi E, Tallarico M, Barlattani A. Clinical and radiological outcomes of two implants with different prosthetic interfaces and neck configurations: randomized, controlled, split-mouth clinical trial. Clin Implant Dent Relat Res. 2014 Feb;16(1):96-106. doi: 10.1111/j.1708-8208.2012.00465.x.

Barwacz CA, Stanford CM, Diehl UA, Qian F, Cooper LF, Feine J, et al. Electronic assessment of peri-implant mucosal esthetics around three implant-abutment configurations: a randomized clinical trial. Clin Oral Implants Res. 2016 Jun;27(6):707-15. doi: 10.1111/clr.12640.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright (c) 2021 Puspa Puspita Lasminingrum, Aldilla Miranda, Dyah Nindita Carolina, Prajna Metta

Downloads

Download data is not yet available.