Banner Portal
Fit of metal-ceramic crowns
PDF

Keywords

Dental marginal adaptation
Crowns
Metal ceramic alloys
Ceramics

How to Cite

1.
Manozzo Kunz PV, Serpa GA, Cunha LF da, Correr GM, Gonzaga CC. Fit of metal-ceramic crowns: effect of coping fabrication method and veneering ceramic application. Braz. J. Oral Sci. [Internet]. 2021 Aug. 27 [cited 2024 Jun. 30];21(00):e225136. Available from: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8665136

Abstract

Aim: To evaluate the influence of cobalt-chromium (Co-Cr) coping fabrication methods and ceramic application on the marginal and internal fit of metal-ceramic crowns. Methods: Co-Cr copings for metal-ceramic crowns were prepared by lost wax casting or CAD-CAM machining of sintered blocks. The fit was analyzed using the silicone replica technique at four assessment points: marginal gap (MG), axial wall (AW), axio-occlusal (AO) angle, and central occlusal (CO) wall. After the initial analysis, the copings were ceramic-veneered with the layering technique, and the fit was again determined. Data were statistically analyzed by paired and unpaired Student’s-t test (α=0.05). Results: Marginal and internal fit before ceramic application according to the coping manufacturing method showed significant differences only at CO (p < 0.001), with milled copings (137.98±16.71 μm) showing higher gap values than cast copings (112.86±8.57 μm). For cast copings, there were significant differences at MG (before 109.13±8.79 μm; after 102.78±7.18 μm) and CO (before 112.86±8.57 μm; after 104.07±10.63 μm) when comparing the fit before and after ceramic firing. For milled copings, there was significant difference only at AO (before 116.39±9.64 μm; after 108.54±9.26 μm). Conclusion: This study demonstrated that the coping fabrication method influenced the internal fit. Ceramic firing maintained or improved the fit of the metal-ceramic crowns. The marginal discrepancy of all restorations, before and after ceramic firing, can be considered clinically acceptable.

https://doi.org/10.20396/bjos.v21i00.8665136
PDF

References

Huang Z, Zhang L, Zhu J, Zhang X. Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology. J Prosthet Dent. 2015 Jun;113(6):623-7. doi: 10.1016/j.prosdent.2014.10.012.

Makhija SK, Lawson NC, Gilbert GH, Litaker MS, McClelland JA, Louis DR, et al. Dentist material selection for single-unit crowns: Findings from the National Dental Practice-Based Research Network. J Dent. 2016 Dec;55:40-7. doi: 10.1016/j.jdent.2016.09.010.

Sola-Ruiz MF, Agustin-Panadero R, Campos-Estelles C, Labaig-Rueda C. Post-fatigue fracture resistance of metal core crowns: press-on metal ceramic versus a conventional veneering system. J Clin Exp Dent. 2015 Apr;7(2):e278-83. doi: 10.4317/jced.52267.

Reitemeier B, Hansel K, Kastner C, Weber A, Walter MH. A prospective 10-year study of metal ceramic single crowns and fixed dental prosthesis retainers in private practice settings. J Prosthet Dent. 2013 Mar;109(3):149-55. doi: 10.1016/S0022-3913(13)60034-7.

Denissen H, Dozic A, van der Zel J, van Waas M. Marginal fit and short-term clinical performance of porcelain-veneered CICERO, CEREC, and Procera onlays. J Prosthet Dent. 2000 Nov;84(5):506-13. doi: 10.1067/mpr.2000.110258.

Della Bona A, Kelly JR. The clinical success of all-ceramic restorations. J Am Dent Assoc. 2008 Sep;139 Suppl:8S-13S. doi: 10.14219/jada.archive.2008.0361.

Knoernschild KL, Campbell SD. Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent. 2000 Nov;84(5):492-8. doi: 10.1067/mpr.2000.110262.

Lang NP, Kiel RA, Anderhalden K. Clinical and microbiological effects of subgingival restorations with overhanging or clinically perfect margins. J Clin Periodontol. 1983 Nov;10(6):563-78. doi: 10.1111/j.1600-051x.1983.tb01295.x.

Colpani JT, Borba M, Della Bona A. Evaluation of marginal and internal fit of ceramic crown copings. Dent Mater. 2013 Feb;29(2):174-80. doi: 10.1016/j.dental.2012.10.012.

Kane LM, Chronaios D, Sierraalta M, George FM. Marginal and internal adaptation of milled cobalt-chromium copings. J Prosthet Dent. 2015 Nov;114(5):680-5. doi: 10.1016/j.prosdent.2015.04.020.

Kim EH, Lee DH, Kwon SM, Kwon TY. A microcomputed tomography evaluation of the marginal fit of cobalt-chromium alloy copings fabricated by new manufacturing techniques and alloy systems. J Prosthet Dent. 2017 Mar;117(3):393-9. doi: 10.1016/j.prosdent.2016.08.002.

Quante K, Ludwig K, Kern M. Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology. Dent Mater. 2008 Oct;24(10):1311-5. doi: 10.1016/j.dental.2008.02.011.

Tamac E, Toksavul S, Toman M. Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns. J Prosthet Dent. 2014 Oct;112(4):909-13. doi: 10.1016/j.prosdent.2013.12.020.

Goldin EB, Boyd NW, 3rd, Goldstein GR, Hittelman EL, Thompson VP. Marginal fit of leucite-glass pressable ceramic restorations and ceramic-pressed-to-metal restorations. J Prosthet Dent. 2005 Feb;93(2):143-7. doi: 10.1016/j.prosdent.2004.10.023.

Holden JE, Goldstein GR, Hittelman EL, Clark EA. Comparison of the marginal fit of pressable ceramic to metal ceramic restorations. J Prosthodont. 2009 Dec;18(8):645-8. doi: 10.1111/j.1532-849X.2009.00497.x.

Bonfante EA, da Silva NR, Coelho PG, Bayardo-González DE, Thompson VP, Bonfante G. Effect of framework design on crown failure. Eur J Oral Sci. 2009 Apr;117(2):194-9. doi: 10.1111/j.1600-0722.2008.00608.x.

Ates SM, Yesil Duymus Z, Caglar I, Hologlu B. The effect of veneering on the marginal fit of CAD/CAM-generated, copy-milled, and cast metal copings. Clin Oral Investig. 2017 Nov;21(8):2553-60. doi: 10.1007/s00784-017-2054-x.

Hong MH, Min BK, Lee DH, Kwon TY. Marginal fit of metal-ceramic crowns fabricated by using a casting and two selective laser melting processes before and after ceramic firing. J Prosthet Dent. 2019 Nov;122(5):475-81. doi: 10.1016/j.prosdent.2019.03.002.

Kocaagaoglu H, Albayrak H, Kilinc HI, Gumus HO. Effect of repeated ceramic firings on the marginal and internal adaptation of metal-ceramic restorations fabricated with different CAD-CAM technologies. J Prosthet Dent. 2017 Nov;118(5):672-7. doi: 10.1016/j.prosdent.2016.11.020.

Cunali RS, Saab RC, Correr GM, Cunha LFD, Ornaghi BP, Ritter AV, et al. Marginal and internal adaptation of zirconia crowns: a comparative study of assessment methods. Braz Dent J. 2017 Jul-Aug;28(4):467-73. doi: 10.1590/0103-6440201601531.

Pedroche LO, Bernardes SR, Leão MP, Kintopp CC, Correr GM, Ornaghi BP, et al. Marginal and internal fit of zirconia copings obtained using different digital scanning methods. Braz Oral Res. 2016 Oct 10;30(1):e113. doi: 10.1590/1807-3107BOR-2016.vol30.0113.

Ogunc A, Yildirim Avcu G. Effect of repeated firings on the marginal and internal adaptation of implant-supported metal-ceramic restorations fabricated with different thicknesses and fabrication methods. J Prosthet Dent. 2021 Mar;125(3):504.e1-504.e6. doi: 10.1016/j.prosdent.2020.10.021.

Han HS, Yang HS, Lim HP, Park YJ. Marginal accuracy and internal fit of machine-milled and cast titanium crowns. J Prosthet Dent. 2011 Sep;106(3):191-7. doi: 10.1016/S0022-3913(11)60120-0.

Ram SM, Ranadive NN, Nadgere JB. Microcomputed tomography a noninvasive method to evaluate the fit of a restoration as compared to conventional replica technique. J Indian Prosthodont Soc. 2019;19(3):233-9. doi: 10.4103/jips.jips_71_19.

McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J. 1971 Aug 3;131(3):107-11. doi: 10.1038/sj.bdj.4802708.

Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig. 2009 Sep;13(3):343-9. doi: 10.1007/s00784-008-0224-6.

Gaintantzopoulou MD, El-Damanhoury HM. Effect of preparation depth on the marginal and internal adaptation of computer-aided design/computer-assisted manufacture endocrowns. Oper Dent. 2016;41(6):607-16. doi: 10.2341/15-146-L.

Borba M, Cesar PF, Griggs JA, Della Bona A. Adaptation of all-ceramic fixed partial dentures. Dent Mater. 2011 Nov;27(11):1119-26. doi: 10.1016/j.dental.2011.08.004.

Reich S, Uhlen S, Gozdowski S, Lohbauer U. Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Investig. 2011 Aug;15(4):521-6. doi: 10.1007/s00784-010-0414-x.

Gurel K, Toksavul S, Toman M, Tamac E. In vitro marginal and internal adaptation of metal-ceramic crowns with cobalt-chrome and titanium framework fabricated with CAD/CAM and casting technique. Niger J Clin Pract. 2019 Jun;22(6):812-6. doi: 10.4103/njcp.njcp_570_18.

Roberts HW, Berzins DW, Moore BK, Charlton DG. Metal-ceramic alloys in dentistry: a review. J Prosthodont. 2009 Feb;18(2):188-94. doi: 10.1111/j.1532-849X.2008.00377.x.

Real-Voltas F, Romano-Cardozo E, Figueras-Alvarez O, Brufau-de Barbera M, Cabratosa-Termes J. Comparison of the marginal fit of cobalt-chromium metal-ceramic crowns fabricated by CAD/CAM techniques and conventional methods at three production stages. Int J Prosthodont. 2017;30(3):304-5. doi: 10.11607/ijp.5038.

Gemalmaz D, Alkumru HN. Marginal fit changes during porcelain firing cycles. J Prosthet Dent. 1995 Jan;73(1):49-54. doi: 10.1016/s0022-3913(05)80272-0.

Regish KM, Sharma D, Prithviraj DR, Nair A, Raghavan R. Evaluation and comparison of the internal fit and marginal accuracy of base metal (nickelchromium) and zirconia copings before and after ceramic veneering: a sem study. Eur J Prosthodont Restor Dent. 2013 Mar;21(1):44-8.

Weaver JD, Johnson GH, Bales DJ. Marginal adaptation of castable ceramic crowns. J Prosthet Dent. 1991 Dec;66(6):747-53. doi: 10.1016/0022-3913(91)90408-o.

Shokry TE, Attia M, Mosleh I, Elhosary M, Hamza T, Shen C. Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations. J Prosthet Dent. 2010 Jan;103(1):45-52. doi: 10.1016/S0022-3913(09)60216-X.

Rahme HY, Tehini GE, Adib SM, Ardo AS, Rifai KT. In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns. J Contemp Dent Pract. 2008 Feb;9(2):25-32.

An S, Kim S, Choi H, Lee JH, Moon HS. Evaluating the marginal fit of zirconia copings with digital impressions with an intraoral digital scanner. J Prosthet Dent. 2014 Nov;112(5):1171-5. doi: 10.1016/j.prosdent.2013.12.024.

Pimenta MA, Frasca LC, Lopes R, Rivaldo E. Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology. J Prosthet Dent. 2015 Aug;114(2):223-8. doi: 10.1016/j.prosdent.2015.02.002.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.

Copyright (c) 2021 Patrícia Valéria Manozzo Kunz, Gabriela Andrade Serpa, Leonardo Fernandes da Cunha, Gisele Maria Correr, Carla Castiglia Gonzaga

Downloads

Download data is not yet available.